Determination of adsorption and desorption parameters from ignition temperature measurements in catalytic combustion systems

 

 

T. Perger1, T. Kovács1, T. Turányi1 and C. Trevińo2

 

1   Eötvös Loránd Tudományegyetem Fizikai Kémiai Tanszék

1518 Budapest, Pf. 32; E-mail: perger@vuk.chem.elte.hu

2   Facultad de Ciencias, UNAM, 04510 México D.F., Mexico

 

 

Exposing a cold catalyst to a fuel-oxygen mixture, the surface gets covered with the more effectively adsorbing species. Increasing the temperature, this species is desorbed and the ignition temperature is determined by the rate of desorption. Based on the equations for the heat balance, expressions were derived for the calculation of ignition temperature from the parameters of the experimental setup, the preexponential factor Ad and activation energy Ed of desorption, the ratio of sticking coefficients, and the ratio of adsorption orders of fuel and oxygen.

Published experimental data for the catalytic ignition of CO, H2 and CH4 were reinterpreted using the expressions obtained and the following parameters were determined for polycrystalline platinum catalyst:

Ed(H2/Pt) = 42.2±2.1 kJ/mole, Ed(CO/Pt) = 118.3±15.6 kJ/mole,

Ed(O2/Pt) = 190±34 kJ/mole, S(H2/Pt)/S(O2/Pt) = 35±10,

S(CO/Pt)/S(O2/Pt) = 48.9±8.1, S(O2/Pt)/S(CH4/Pt) = 5.8±0.3.

Error limits refer to confidence level of 0.95. The activation energy of desorption for CO and O2 and the ratio of zero coverage sticking coefficients of O2 and CH4 are the first experimentally based determinations of these parameters. Experimental ignition temperatures could be reproduced assuming second order adsorption of CO, H2 and O2 on Pt surface. These reaction orders have been debated in the literature.